翻訳と辞書
Words near each other
・ "O" Is for Outlaw
・ "O"-Jung.Ban.Hap.
・ "Ode-to-Napoleon" hexachord
・ "Oh Yeah!" Live
・ "Our Contemporary" regional art exhibition (Leningrad, 1975)
・ "P" Is for Peril
・ "Pimpernel" Smith
・ "Polish death camp" controversy
・ "Pro knigi" ("About books")
・ "Prosopa" Greek Television Awards
・ "Pussy Cats" Starring the Walkmen
・ "Q" Is for Quarry
・ "R" Is for Ricochet
・ "R" The King (2016 film)
・ "Rags" Ragland
・ ! (album)
・ ! (disambiguation)
・ !!
・ !!!
・ !!! (album)
・ !!Destroy-Oh-Boy!!
・ !Action Pact!
・ !Arriba! La Pachanga
・ !Hero
・ !Hero (album)
・ !Kung language
・ !Oka Tokat
・ !PAUS3
・ !T.O.O.H.!
・ !Women Art Revolution


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

computer automated measurement and control : ウィキペディア英語版
computer automated measurement and control

Computer Automated Measurement And Control (CAMAC) is a standard bus and modular-crate electronics standard for data acquisition and control used in nuclear and particle physics experiments and in industry. The bus allows data exchange between plug-in modules (up to 24 in a single crate) and a crate controller, which then interfaces to PC or to a VME-CAMAC interface.
The standard was originally defined by the ESONE Committee〔(The ESONE committee )〕 as standard EUR 4100 in 1972,〔http://www.cern.ch/ESONE/hibernation.pdf ESONE letter〕 and covers the mechanical, electrical and logic of a parallel bus (dataway) for the plug-in modules. Several standards have been defined for multiple crate systems including the Parallel Branch Highway definition and Serial Highway definition. Vendor specific Host/Crate interfaces have also been built.
The CAMAC standard encompasses IEEE standards:
* 583 The base standard
* 683 Block transfer specifications (Q-stop and Q-scan)
* 596 Parallel Branch Highway systems
* 595 Serial highway system
* 726 Real-time Basic for CAMAC
* 675 Auxiliary crate controller specification/support
* 758 FORTRAN subroutines for CAMAC.
Within the dataway, modules are addressed by slot (geographical addressing). The left-most 22 slots are available for application modules while the right-most two slots are dedicated to a crate controller. Within a slot the standard defines 16 subaddresses (0–15). A slot commanded by the controller with one of 32 function codes (0–31). Of these function codes, 0–7 are read functions and will transfer data to the controller from the addressed module, while 16–23 are write function codes which will transfer data from the controller to the module.
In addition to functions that address the module, the following global functions are defined:
* I – Crate inhibit
* Z – Crate zero
* C – Crate clear
The original standard was capable of one 24-bit data transfer every microsecond. Later a revision to the standard was released to support ''short cycles'' which allow a transfer every 450 ns. A follow on upwardly compatible standard ''Fast CAMAC'' allows the crate cycle time to be tuned to the capabilities of the modules in each slot.
The FASTBUS standard was introduced in 1984 as a replacement for CAMAC in large systems.
== Backplane physical characteristics ==

The physical connector on the back of a CAMAC module is a card-edge connector, with a receiving socket on the backplane. Because there are no alignment pins on the socket or connector, there is the possibility of connector misalignment upon module insertion. Therefore, CAMAC modules may NOT be hot-swapped. Many devices are connected to it.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「computer automated measurement and control」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.